Pre-tender condition survey of the 1903 slate roof on the west elevation. Confirms the case for full renewal: c.18% of slates failing, lead flashings perished at three valleys, and previous patch repairs accelerating water tracking into the Captain's Room.

Record date
09 Jun 2026
Recorded by
Blair Smith
Architect & Director, John Frulani Architects
Intelligence source
Site survey
Course
Forfar Golf Club
Angus

Key Observations

Captured findings from the record

  • Issue

    West valley flashing — lead substantially perished; tracking visible on internal plaster.

  • Issue

    South-west pitch — sample area shows 18% slate failure; consistent with renewal rather than patch.

  • Issue

    Captain's Room ceiling — fresh staining since last inspection; heritage joinery at risk.

  • Note

    Chimney stack flaunching — recent works in good order.